FIELD RETRO-FIT DELTA MODULE - CONSUMER

Replacement for 9µf Black Dot PCB's Installation Instructions

3. Remove the reverse switch. as shown in Figure #3 Note: Leave spring clip in housing.

 

(Figure #3)

     

4. Remove the black box and electonics from the switch housing as shown in Figure #4.

5. Remove the wire nuts from the red and brown motor wires, cut the black wire from the pull chain switch as shown in Figure #4.

Note: If wire nuts where not use, cut off wires as close to the plug as possible. Then strip back the BLACK, RED and BROWN wires 1/2"

 

 

(Figure #4)