Normal Start-Up Procedure For W-21
Insert batteries |
W-21 displays temperature
after 20 second warm-up |
|
Press and hold TEST for 3 seconds |
W-21 beeps
then displays 'PRESET CHANNEL' number |
Momentarily press TEST |
Control display
returns to normal, shows ambient
temperature and is ready for use |
Normal Start-Up Procedure For Fan
Turn on power |
Wait 20 seconds
for fan electronics warm-up |
|
Next 120 seconds |
Code acceptance
window |
Fan Microprocessor
Normal Start-Up
After power is applied
to the fan RCM it takes 20 seconds for the microprocessor
to warm-up and stabilize.
During this time the
microprocessor runs its own self check and then reads
the last channel identity code stored in the NOVRAM memory
chip.
Throughout the 20 second
self check period the fan will not accept any transmitted
signals.
After a successful self
check the microprocessor allows up to 120 seconds for
receipt of a new channel identity code and will reprogram
the NOVRAM memory chip.
After 140 seconds from
power turn on, the RCM blocks further access to the NOVRAM
memory chip, re-reads the channel identity code now stored
in the NOVRAM, and is ready for operation. |
|

To change the operating channel
of a fan:
Press and hold
the TEST button.
The control
display will freeze and after about 3 seconds the control
will beep rapidly and display the current 'SET' channel
in place of the temperature.
Press
the fan UP or DOWN buttons:
This will change the indicated control 'SET' channel
number. Stop at a channel number that is not being used
in the area.
|
USE ONLY CHANNELS
49 THROUGH 63 |
 |
NOTE: You have
twenty seconds in which to make a change. The control
will return to normal operation unless a control is pressed.
Press TEST to
memorize the new 'SET' channel:
The W-21 returns to normal operation
and displays the original fan settings.
NOTE: Installing fresh batteries in the W-21 will cause
the control to return back to the original factory 'PRESET
CHANNEL'. |