INSTALLATION INSTRUCTIONS
RMM Conversion
Kit P/N 0001880

1. Turn off power at its source (fuse or circuit breaker)

2. Remove blades and blade holders, light fixture and/or switch housing cap.

3. Remove bottom plate and center band.
 
Circuit Breaker Box
Fuse Box

4. Disconnect both the AC/Motor and BFR connector from the RMM assembly.
 

5. Remove both the RMM and the BFR. These will not be reused.

A. Remove two (2) screws on each side of the RMM-I.

B.Remove the BFR by peeling it off of the motor. Make sure that all orange pieces of rubber has been removed, the NEW BFR will need a clean surface to stick to.

 

 




   

 

 