BFR Replacement - CONTINUED
Hi-Rel
BFR Replacement
To test or replace a BFR it is necessary to partially
disassemble the fan.
| CAUTION:
SHARP BENDING OR FOLDING OF THE BFR COULD DAMAGE IT.
HANDLE WITH CARE. |
1. TURN POWER OFF BEFORE DISASSEMBLING THE FAN.
2. Remove the
blades and blade holder assemblies.
3. Remove the housing
thru-bolts while holding the bottom plate in place.
4. Remove the
bottom plate and center band.
5. To test for
a defective BFR remove the BFR connector from the RMM
board and plug a new BFR into the RMM board. If the problem
is eliminated, replace the BFR as follows:
To remove the defective
BFR, the RMM support shroud must first be removed. To
do this, first remove both connectors from the RMM board
by grasping the edges and gently pulling out with a very
slight rocking motion. Loosen the two support screws to
remove the RMM support. Now completely remove the two
support screws. CAREFULLY peel the BFR from the motor
housing, starting at one end. Clean any remaining adhesive
from the motor using naphtha or lighter fluid.