FAN PREPARATION



Step 1.

Prepare for fan installation as follows:

Step 1A.
If the pole was removed from the fan, route the wires from the motor through the Perma•Lock™ downrod and ball assembly.

Tip: The downrod has a tapered thread that is designed to lock completely when correctly installed.

Step 1B. Thread the downrod into the motor coupling until it stops turning, this will take at least four and a half full turns.

Step 1C. Securely tighten the locking bolt to ensure safe operation of your fan

CAUTION: Failure to fully lock in the downrod before securely tightening the locking bolt may cause the fan to separate from the downrod and fall during normal operation!
 
HANGING THE FAN
Step 2. To hang the fan body in the canopy, hold the fan body firmly and insert the ball into the canopy opening. Check that no wires were pinched. Rotate the fan body until the slot in the nylon ball fits into the pin opposite the canopy opening.

 

 
CANOPY ELECTRICAL CONNECTIONS
Step 3a. Attach the fan wires to the ceiling fixture outlet box wiring by twisting the bare ends of the wires together and then securing with a wire nut. Test that the connection is secure by pulling on the wire nut. Connect in this order:

Step 3b. Inteli-Touch Wiring Connections

• GREEN leads from mounting plate and fan to GROUND conductor of power source.
Secure with wire nut.

• WHITE wire from fan to WHITE neutral wire in ceiling fixture outlet box.
Secure with wire nut.

• BLACK power wire from fan to BLACK power wire in ceiling outlet box.
Secure with wire nut.

 

CANOPY HATCH INSTALLATION
Step 4. Tuck the wires into the canopy with the wire nuts pointed upwards, so that the WHITE and BLACK wires are on opposite sides of the canopy and all wires are clear of the canopy opening.

Step 5. Install canopy hatch with the last canopy screw and lock washer. To do this, tilt the fan body away from the hatch opening. Tighten the screws firmly by hand only.

Step 6. Straighten the fan, then check to ensure that there is no movement between the canopy and ceiling or Hang-Tru ball and top support shaft.

 